Fire Sprinkler System – Moda Engineering https://modaengineering.com Thu, 26 Jun 2025 22:08:57 +0000 en-US hourly 1 https://wordpress.org/?v=7.0 https://modaengineering.com/wp-content/uploads/2025/05/Moda-Fav-100x100.png Fire Sprinkler System – Moda Engineering https://modaengineering.com 32 32 Alarm Check Valve https://modaengineering.com/product/alarm-check-valve/ Thu, 22 May 2025 18:14:12 +0000 https://techieprime.net/modae/?post_type=product&p=949 Key Features:
  • Water Flow Monitoring: Detects water movement and activates alarms to signal sprinkler system engagement.
  • Backflow Prevention: Functions as a check valve to stop water from flowing backward, protecting the system.
  • Integrated Alarm Mechanism: Equipped with an internal switch for audible or visual alarms, alerting staff instantly.
  • Durable Construction: Made from brass, stainless steel, or ductile iron to withstand harsh environments and ensure longevity.
  • Compact and Easy to Install: Space-saving design suitable for residential, commercial, and industrial systems.
Specifications:
  • Materials: Stainless steel, ductile iron, bronze (application-dependent)
  • Size Range: Typically 2" to 6" diameter
  • Pressure Rating: Standard 175 PSI, up to 250 PSI available
  • Flow Capacity: 50 to 1500 GPM depending on size and system needs
  • Alarm Contact: Dry contact output for connection to external alarm systems
  • Temperature Range: Operates from 0°C to 66°C
Compliance: UL listed, FM approved, NFPA compliant]]>
Key Features:
  • Water Flow Monitoring: Detects water movement and activates alarms to signal sprinkler system engagement.
  • Backflow Prevention: Functions as a check valve to stop water from flowing backward, protecting the system.
  • Integrated Alarm Mechanism: Equipped with an internal switch for audible or visual alarms, alerting staff instantly.
  • Durable Construction: Made from brass, stainless steel, or ductile iron to withstand harsh environments and ensure longevity.
  • Compact and Easy to Install: Space-saving design suitable for residential, commercial, and industrial systems.
Specifications:
  • Materials: Stainless steel, ductile iron, bronze (application-dependent)
  • Size Range: Typically 2" to 6" diameter
  • Pressure Rating: Standard 175 PSI, up to 250 PSI available
  • Flow Capacity: 50 to 1500 GPM depending on size and system needs
  • Alarm Contact: Dry contact output for connection to external alarm systems
  • Temperature Range: Operates from 0°C to 66°C
Compliance: UL listed, FM approved, NFPA compliant]]>
Test and Drain Valves https://modaengineering.com/product/test-and-drain-valves/ Thu, 22 May 2025 18:13:21 +0000 https://techieprime.net/modae/?post_type=product&p=947 Deluge Valves https://modaengineering.com/product/deluge-valves/ Thu, 22 May 2025 18:12:06 +0000 https://techieprime.net/modae/?post_type=product&p=946 Deluge systems have open sprinkler heads and are activated when a fire detection system triggers the release of water. These are ideal for high-hazard areas, including chemical plants or areas with highly combustible materials.
Specifications of Fire Sprinkler Systems
  • Sprinkler Head Types: Upright, pendent, sidewall, and concealed heads for all installation environments.
  •  K-Factor Range: 2.8 to 25.2 (discharge coefficient), ensuring optimal water flow based on your system's needs.
  •  Temperature Ratings: Sprinkler heads designed to activate at temperatures ranging from 57°C to 141°C.
  •  Materials: Premium brass, stainless steel, and chrome-plated finishes for added strength and longevity.
  •  Finish Options: Available in brass, white, chrome, black, and custom painted finishes.
  •  Compliance: Fully compliant with international standards, including UL, FM, and NFPA 13.
]]>
Deluge systems have open sprinkler heads and are activated when a fire detection system triggers the release of water. These are ideal for high-hazard areas, including chemical plants or areas with highly combustible materials.
Specifications of Fire Sprinkler Systems
  • Sprinkler Head Types: Upright, pendent, sidewall, and concealed heads for all installation environments.
  •  K-Factor Range: 2.8 to 25.2 (discharge coefficient), ensuring optimal water flow based on your system's needs.
  •  Temperature Ratings: Sprinkler heads designed to activate at temperatures ranging from 57°C to 141°C.
  •  Materials: Premium brass, stainless steel, and chrome-plated finishes for added strength and longevity.
  •  Finish Options: Available in brass, white, chrome, black, and custom painted finishes.
  •  Compliance: Fully compliant with international standards, including UL, FM, and NFPA 13.
]]>
Zone Control Valves https://modaengineering.com/product/zone-control-valves/ Thu, 22 May 2025 18:10:54 +0000 https://techieprime.net/modae/?post_type=product&p=944 Zone control valves are essential in both sprinkler systems and deluge systems, allowing firefighters to target specific areas while maintaining pressure and flow to unaffected zones. These valves are typically connected to an alarm system, which notifies operators of system activation or any changes in water flow.
Key Features
  • Precise Control: Allows for individual control of water flow to specific areas or zones in a building.
  •  Automatic Operation: The valve assembly can be automatically activated by fire detection systems or manually operated, depending on the system design.
  •  Flow Monitoring: Integrated with flow switches and pressure gauges, it helps monitor the system's operation and identify flow abnormalities.
  •  Safety & Isolation: Helps isolate damaged sections of the system to maintain the operation of unaffected areas during maintenance or fire events.
  •  Reliable Alarm Integration: Includes alarm contacts that can be connected to external monitoring and alarm systems to alert personnel of changes in valve status.
]]>
Zone control valves are essential in both sprinkler systems and deluge systems, allowing firefighters to target specific areas while maintaining pressure and flow to unaffected zones. These valves are typically connected to an alarm system, which notifies operators of system activation or any changes in water flow.
Key Features
  • Precise Control: Allows for individual control of water flow to specific areas or zones in a building.
  •  Automatic Operation: The valve assembly can be automatically activated by fire detection systems or manually operated, depending on the system design.
  •  Flow Monitoring: Integrated with flow switches and pressure gauges, it helps monitor the system's operation and identify flow abnormalities.
  •  Safety & Isolation: Helps isolate damaged sections of the system to maintain the operation of unaffected areas during maintenance or fire events.
  •  Reliable Alarm Integration: Includes alarm contacts that can be connected to external monitoring and alarm systems to alert personnel of changes in valve status.
]]>
Sprinklers https://modaengineering.com/product/sprinklers/ Thu, 22 May 2025 18:09:12 +0000 https://techieprime.net/modae/?post_type=product&p=939